High Efficiency Gas Furnace Utilizing Electronic Ignition
 |
Gas furnaces, boilers, and water heaters have evolved from the basic standing pilot ignition system to the state of the art electronic ignition models. Standing pilot gas furnaces relied on keeping a pilot flame lit for the furnace, boiler, or water heater to function. The advent of electronic ignition has made it possible to prove a flame without keeping a pilot light lit 24/7 and thereby saving money because electronic ignition only needs to have a flame when there is a call for heat from the thermostat.
Typically, electronic ignition is comprised of a manufacturers OEM circuit board or an after-market ignition control module located near the gas valve of the furnace, boiler, or water heater. The gas valve is controlled directly by this circuit board or ignition module whereby the standing pilot gas valve is usually controlled by the thermostat. There are different versions of gas furnace electronic ignition systems but they all serve the same purpose and function and that is to safely heat your dwelling. Among these types of gas furnace electronic ignition systems there are:
- Direct Spark Ignition - this version has no pilot light at all. It lights the main burners on a call for heat and a state of the art flame sensor detects a flame. If no flame is detected on a try for ignition the gas valve closes. After a specified amount of time, usually seconds, the ignition module will try ignition again. Again, if the flame sensor detects no flame a delay before trying again will occur. Typically after three failed trials for ignition with the flame sensor not detecting a flame the ignition module will go into a lock-out mode for at least an hour (most models). This is a safety measure to prevent a dangerous build up of gas. If the module endlessly tried for ignition the un-ignited gas could build up to dangerous levels and an explosion could occur. *The spark coming from the gas furnace circuit board or ignition control module can exceed 10,000 volts so caution is advised.
- Intermittent Pilot Ignition - this version has a pilot light which only lights on a call for heat. The pilot light is located near the main burner and on a call for heat the ignition module or gas furnace circuit board opens the pilot valve inside the gas valve and initiates a spark at the head of the pilot assembly to light the pilot light. The flame sensor is also located at the pilot assembly and as soon as the flame is detected the gas furnace circuit board or ignition control module opens the main valve inside the gas valve. The pilot light then lights the main burners. When the thermostat is satisfied all gas control components& shuts off until the next call for heat. If a flame is not sensed then a trial for ignition will repeat itself for up to four trials and then the gas controls will be locked out for a specified period of time (a minimum of an hour depending the gas furnace or gas controls manufacturer)when a new sequence will start over again. *The spark coming from the gas furnace circuit board or ignition control module can exceed 10,000 volts so caution is advised.
- Hot Surface Ignition - hot surface ignition can be either direct fire or indirect fire to a pilot (Honeywell Smart Valve is an example of indirect fire to a pilot). The igniter is a silicon carbon element which glows red hot when voltage is applied to it. On a call for heat, the gas furnace circuit board or ignition module sends a specified amount of voltage to the igniter. After a small timed delay and after the igniter is glowing red hot, the main valve opens in the gas valve. The gas strikes the silicon carbon element and ignition occurs. A flame sensor located near the burners detects the flame and the main burners remain lit and the voltage is taken away from the hot surface igniter. If a flame is not sensed then a trial for ignition will repeat itself for up to four trials and then the gas controls will& be locked out for a specified period of time (a minimum of an hour depending on the gas furnace or gas control manufacturer) when a new sequence will start over again.
- Mercury Bulb - this system uses a mercury switch to prove there is a flame on a pilot light. Mercury bulb systems usually use spark ignition to light a pilot and the mercury switch proves the flame. Once the switch proves the flame the main valve in the gas valve opens and the pilot lights the main burners. Mercury is very hazardous to the environment and not many manufacturers use this type of electronic ignition.
It is important to note that all these systems work in a furnace sequence of operation as determined by the controller. If the furnace safety controls detects a problem with any of the safeties, including the furnace flame sensor, the furnace sequence of operation will be interrupted on a lock-out. Furnace sequence of operation varies from furnace to furnace and it is important to know the furnace sequence of operation to troubleshoot the system if a problem exists and the furnace is locking out the ignition of the furnace.
 |
|
Last Updated ( Sunday, 02 March 2008 10:32 )
|
Download Your Favorite TV Shows and Video
HVAC Product Reviews
HVAC Product Reviews
 |
Everyone is a critic and now is your chance to be a published critic. High Performance HVAC offers this new website as a way for people to review equipment or to research the next product they will purchase. See what other people said about their new (and old) HVAC equipment and products they purchased. Read the Reviews and Write a Review Yourself... |
HVAC Jobs
HVAC Jobs and Careers
 |
High Performance HVAC System is proud to announce our partnership with CareerBuilder.com. CareerBuilder.com and High Performance HVAC Systems can give you the tools to energize your career or help you get a job in the field of HVAC. Recommend a friend who is seeking employment or use it to see who is hiring in your area. High Performance HVAC Systems & CareerBuilder.com also offers many other tools like salary calculators, career and job advice, and all the latest career and job news to keep you in the know and one step ahead of others. Visit the High Performance HVAC Jobs and Careers Search Engine... |
HVAC Video Reviews
HVAC Video Reviews
 |
This is a new add-on to High Performance HVAC Systems. We have several video reviews there to keep you busy and as soon as we finish getting the old High Performance HVAC site back to normal on a new program we'll continue adding more videos for your enjoyment and comments. Read the Reviews and See the Videos... |
Contribute to HVAC
Contribute to HVAC
We are seeking people who want to contribute to HVAC by writing articles to be published here on High Performance HVAC. Whether you are a homeowner, HVAC technician, HVAC Contractor, related trade, or in the HVAC industry in some way we invite you to write article(s) for the site which pertain to HVAC. We will review the articles and notify you if and when they will be published. Homeowners can write about an air conditioning and heating system they had installed or serviced and their view on the service they received. Technicians can contribute by writing about technical things or dealing with management. High Performance HVAC has the final editorial say before any article is published. You can either email articles to us using the contact page or you can register at High Performance HVAC and use the automated article submission link. Conditions do apply. For further information send us an email. |
|
Learning, Improvement, & Technical Resources - Self Improvement Paths
Donate to High Performance HVAC
Why Donate?
Why Donate?Donate to High Performance HVAC to help us continue offering advice on HVAC systems and energy efficient ideas which helps empower people, save energy, and help the environment. With your generous support we can continue to expand High Performance HVAC and offer information that reduces energy usage and cost so that people can be more comfortable and use energy wisely. HVAC Systems consume a lot of energy and with the energy saving information we offer here at High Performance HVAC we help people contribute to a green planet.
We take a common sense approach to saving energy and reducing bad emissions that harm the environment. Every little bit helps and your donation can help us offer more articles, graphics, and other visual aides that educate people and HVAC technicians to use energy more wisely. Donate on a secure connection and help us take a practical approach to helping a greener planet for everybody. If you have any questions or would like to donate more than the maximum allowed by Paypal please use our contact form to contact us. Thanks!
|