Standing Pilot Gas Furnace Systems

Furnaces, water heaters, and boilers, especially older gas systems use the standing pilot gas system as an integral part of the furnaces operation. These systems are best recognized as having a standing flame burning continuously. It is a basic and time tested system which provides a reliable way of proving a flame. It employs a thermocouple (some systems can use a thermopile which is a lot of thermocouples embedded in one piece) and a gas valve which has two separate valves inside of it. One of these valves is the primary valve which operates directly from the thermostat. It will open and close when the thermostat calls for heat provided the pilot valve is open. If the pilot valve is closed then gas will not be provided to the burners when there is a call for heat. The pilot valve will remain open as long as there is a pilot flame and the thermocouple (or thermopile) is present and in good working order. The standing pilot is basically a reliable and time tested way of proving that a flame is present before allowing the main or primary valve to open and introduce a significant volume of gas (natural or propane) to the main burners.

Thermocouple or Thermopile for Standing Pilot Gas Furnace Systems

A thermocouple (or thermopile) is necessary for the standing pilot to function. Technically it is called a Coppel element but most HVAC technicians refer to it as thermocouple. It is made of nickel and copper and when heat is applied to it it produces a very small voltage. These two dissimilar metals create a tiny voltage when they are heated. In a standing pilot gas system, the gas valve utilizes the pilot valve. What controls this pilot valve? Of course it is the solenoid which is powered by the voltage produced by the thermocouple. This solenoid requires a tiny amount of voltage to keep the pilot valve open. If, for whatever reason, the thermocouple (or thermopile) cools off, then the pilot valve in the main gas valve closes and prevents gas from moving through the valve and into the main burners. Why? Because we do not want gas going through the main valve without having a way if igniting the initial rush of gas. If gas was allowed to escape without igniting it could build up into a dangerous concentration. A potentially explosive concentration. The time tested and reliable standing pilot system offers a safe and proven flame proofing system. It is slowly being replaced by more modern systems but they do remain as a reliable system to prove a flame for the purpose of igniting the main burners on a call for heat.

Standing Pilot Gas Furnace Sequence of Operation

As long as there is a pilot light the following sequence is typical of most standing pilot gas furnace systems. Sequence of operation varies from manufacturer to manufacturer and system to system but the following represents the most common sequence of operation for standing pilot gas furnaces.

  • with a lit pilot light the thermostat calls for heat and the heating contacts in the thermostat close.
  • the main valve opens and introduces gas to the main burners. The gas touches the pilot flame and is ignited.
  • with the ignition of gas on the main burner heat begins to build up in the heat exchanger where there is a device which senses heat.
  • When the heat in the heat excahanger reaches a designated set point, the device closes a switch which engages the blower motor.
  • The blower motor introduces warm air throughout the ductwork and the dwelling.
  • The thermostat satisfies as the heat reaches set point. The main valve closes and the main burners cease burner with the lack of gas. The blower continues to run to dissipate the heat.
  • As the heat exchanger cools the device which senses heat in the heat exchanger cools also. When the temperature inside the exchanger reaches a certain set point, contacts open and the blower disengages stopping all air flow until the next call for heat the sequence of operation begins anew.

 

Hits: 3559
Comments (1)Add Comment
0
homewoner
written by Rafael Pastor, October 31, 2008
Do you have a catalog available. If so please send me one at:
Rafael Pastor
1782 Lawrence St.
Rahway, NJ 07065.

Thanks a lot/

Write comment

security code
Write the displayed characters


busy
Last Updated on Friday, 28 November 2008 21:08
 

HVAC Product Reviews

thermostats, honeywell thermostats, thermostats selection
Everyone is a critic and now is your chance to be a published critic. High Performance HVAC offers this new website as a way for people to review equipment or to research the next product they will purchase. See what other people said about their new (and old) HVAC equipment and products they purchased. Read the Reviews and Write a Review Yourself...

HVAC Jobs and Careers

hvac jobs, hvac careers, hvac job search engine
High Performance HVAC & CareerBuilder.com offers many tools like salary calculators, career and job advice, and all the latest career and job news to keep you in the know and one step ahead of others. Visit the High Performance HVAC Jobs and Careers Search Engine... Find a good HVAC Career with High Performance HVAC and Careerbuilder.com

HVAC Books and Education

Knowledge is Power - Empower Yourself
The foundation of a good technician is a good education. The philosophy of a good technician is to never stop learning new things. Always expand your knowledge base and yes sometimes that means going back to the basics. Always strive to learn more. Recommended books to help improve your knowledge in HVAC...

Who's Online

We have 20 guests online

Learn - Read - Succeed